Victron Community - Topics tagged professional

Topics tagged professional

SmartShunt never syncs to 100 % – BMS cuts off while charge current is above 10 % tail current

Hi all, I’m using a SmartShunt on 48 V lithium batteries with an internal BMS. The charger charges at a constant ~30 A right up to the moment the BMS disconnects at full charge. There is no absorption phase and no current taper. Because the current is still above the maximum tail current (10 %) at cut-off, the SmartShunt’s sync condition is never met. The SOC never resets to 100 % and drifts over time. The SmartShunt and Cerbo GX are powered from the battery, so after the cut-off everything is…

How to find out where my CVL/ Setpoint is coming from

Hey There I got a Remote installation where they have a Problem with the VE.Bus System charge Voltage Setpoint. System overview: 1x 10kWh Sodium Ion Battery (Natbatt) 3x Multiplus II 48/3000/35-32 3Ph/400V Configuration 1x Cerbo GX 1x Energy Meter Carlo Gavazzi over RS485 1X Fronius Symo 7.0 1x Solar Manager (Customers Choice) This was an Old Salidomo System, where batteries got Replaced and also the Venus GX Replaced to an CerboGX. The Salidomo Batteries got Faulty after only a few years. The…

Welche modernen Module für den Multi RS19 Solar?

Hallo liebe Community, ich habe mir das Datenblatt für den Multi RS 19 Solar angeschaut und dabei ist mir der Impp (“maximale betriebliche Eingangsstrombegrenzung”) aufgefallen. Mit 12 A ist dieser meiner Meinung für heutzutage übliche Module sehr niedrig. Wenn ich mit 1762 x 1134 x 30 mm suche, finde ich eigentlich nur die TSM-xxxNEG9R.28 Serie, wenn ich mir ein bisschen Spielraum bei den genauen Außenmaßen lasse, finde ich noch die REC Alpha Pure-RX. Da wir in großen Chargen bestellen die uns…

Multiplus 2 AC Out 2 Relay with assistants cycling on/off

I am trying to support a customer with an issue on the relay control of AC Out 2 on Multiplus 2 48V 3000VA (Easysolar 2). I’m testing the setup with most recent firmware versions (Multiplus V562, GX: v3.80). Pylontech battery connected and communicating with the GX device, SOC shows up as normal, no issues here. The goal is to create a very basic configuration where the AC Out 2 turns on when the SOC goes over a certain limit, and off when SOC goes below a threshold. No other assistants used,…

Lead acid equalization controls changed?

Good evening, We just witnessed that the choice in VRM console is changed about the equalization of lead acid batteries without updating any firmware on the installs. Before, choice, after EQ go to float or after EQ go to absorption, now, that choice is gone in VRM. Tomorrow, we will check a local install directly from a GX display, and see it works still from there… Any others noticed this recently? Regards, Jeroen. 40 posts - 6 participants Read full topic

MPPT RS450 / 200 - Wie wird die ISO Messung gemacht?

Hi, Wie macht der MPPT RS die ISO Messung? Ich sehe oft schwankende ISO Werte wenn die Stringspannung noch stark schwankt: Morgens beim anlaufen oder Abends kurz vorm abschalten. Auch ohne Sonne: Oft 100MOhm - aber dann gehts mal runter auf 50MOhm um dann wieder langsam bis 100MOhm zu steigen… daher interessiert mich wie gemessen wird intern, um zu verstehen was da passiert. Viele Grüße Broesel 2 posts - 2 participants Read full topic

Switch Pane Switches to show Current

With the integration of all of these NMEA digital switching devices, shelly devices and virtual switches, it would be great if the individual switches in the switch pane could show the load current from the device/virtual switch. The virtual switch could easily have an input added to this for the current to be fed into. The current could possibly be displayed in place of the “On” value once the switch is on and current is being received, if no current value is received leave “On” there. Or as a…

How to limit shore charging to a specific SOC range (e.g. 20% → 60%)?

Hi everyone, We are working on several marine applications using Victron systems with lithium batteries, Cerbo GX, Quattro/MultiPlus and MPPT solar chargers. Previously, we did not need to implement any special software logic for battery SOC limits. However, with larger solar arrays on newer boats, we are now facing a different requirement. When the boat is connected to shore power in the marina, the customer does not want the batteries to be charged to 100% continuously. Can this type of…

VictronConnect: an improved system dashboard

Hi all, The system dashboard in the VictronConnect app has been rebuilt: The system overview now shows your system in interactive elements. Tap a card and its detail view opens from the bottom, with the full graphs. The grid card opens the import and export breakdown, the Dynamic ESS card opens a tabbed view with the energy, the schedule and the costs, and the status card shows the alarms that fired last. The rest is in this short deck, including dark mode and examples of a Multi RS, a marine…

MultiRS 3 Phase System - AC PV Enphase Micro Inverters POWER CUT

Hi Everyone, A few days ago we had a power cut, and so the house with the solar micro inverters on the output had still power because of the UPS function. 3x Multi RS off-grid: DESS holds battery charge rate at 0 W, system frequency-shifts the AC-coupled PV off for 2 hours. SYSTEM 3x Multi RS Smart 48V/6000VA/100A, one per phase (L1/L2/L3), firmware v1.31 Cerbo GX MK2, Venus OS v3.79 Enphase microinverters on AC-out, read in as a SunSpec PV inverter, 6.48 kW total devided over 3 phases. Grid…

VRM release notes 09-09-2026

Hi all, I would love to share with you the latest changes that were just added to production VRM: The dashboard icons got a fresh look. Grid, AC Loads, Essential Loads, Consumption and Dynamic ESS have new icons, and so does the weather forecast. The dashboard now shows a DC Sources card. If your system has an alternator, a fuel cell, or an Orion XS / SmartShunt configured as a DC source (for example a wind or shaft generator), you will see it flow into the battery, just like the Remote Console…

Attention distributors/dealers/installers: Adler EF3 fuses Available in the USA

After quite some time lobbying Adler Electric USA to bring their 36x22mm EF3 fuses to North America, they are now planning to stock them in their Seattle warehouse. If you’re not familiar with these fuses, then search the forum for EF3 fuses or see one discussion here: Fuses and Wattloss on T Class MEGA EF3 and DC Breakers For those not in the know, these are popular in Europe to replace MEGA fuses in a Lynx Distributor or a Lynx PowerIn with the extra studs added. They are physically…

Multi HS19 Solar 15k

Just got the email from Victron on releasing the Multi HS19 Solar 15k. Congratulations! As an installer, it looks interesting for small to medium scale business applications. Despite my strong preference for the Victron ecosystem and software, so far I haven’t considered them in such projects due to the amount of inverters+space and lack of server-rack support. This one however has all 3 phases in one unit and works with a rack, with a better (not great) solar input voltage range. There’s a few…

Fault condition during microgrid operation

Hello, For some time now, I’ve been testing and using the new microgrid system, and I hadn’t encountered any major problems until now. Fews days ago, one of my Victron system fell down during operation and indicated “Fault condition” with the alarm : To resolve it, I needed to reconfigure my quattros with a new VE.Configure configuration (in fact the same configuration as before, I just removed the Microgrid assistant). After that, this first vitron system became functional again. But today,…

frequencyVariationOccurred causing repeated inverter power reduction

Dear community, i have an issue with my Victron system. I am using 3x MultiPlus II 48V/15000 in a three-phase system connected to the grid with a VM-3P75CT meter. Both the grid connection and all loads are on AC Input. The frequencyVariationOccurred flag appears regularly, and every time it happens, the inverter power is reduced. This occurs approximately every 5–10 minutes. I have already tried different grid code settings, including running without a grid code, with LOM enabled, and with LOM…

Frequency shifting et délai de déblocage des onduleurs PV

Bonjour, Lorsqu’un multiplus utilise la fonction frequency shifting pour freiner la production photovoltaïque d’onduleur réseau, il augmente sa fréquence jusqu’à parfois bloquer les onduleur PV. Le délai pour débloquer ces onduleurs est parfois très longue (quelques heures), comment réduire ce délai ? Merci pour votre aide 8 posts - 4 participants Read full topic

One case of MultiPlus II transformer hum diagnosed

I recently investigated a noise complaint, loud transformer hum from a MultiPlus II 5kVA running ESS. The inverter is installed in the attic and the people sleeping in the bedroom below were complaining about the loud hum transmitted through the building structure every evening. But when I was on site, the hum was not audible. After a while, mostly by accident, we found that the loud hum appears under very specific conditions: when the dishwasher is running. They were starting the dishwasher…

EV charging station mise à jour charge bidirectionnelle (V2H)

Bonjour, Savez vous si une mise à jour est prévue pour la EV charging station afin qu’elle devienne bidirectionnelle vers le logement (V2H - vehicle to home) ? Afin d’utiliser son véhicule électrique comme une batterie résidentiel. Merci de vos réponses. Bonne journée. Cordialement 4 posts - 3 participants Read full topic

Improvements to VRM and New UI for DC only systems

We need better visualization in VRM and new UI for DC only systems such as cars (campers) and DC only (or AC->DC) powered telco equipment. See these images from the same setup: First - it shows Inverter Off and AC load when there are none. These boxes shouldn’t be visible at all. In System setup - position of AC load should be option of no AC loads present. Second - Alternator (via Orion XS 1400) is shown in GUI (great) but no in VRM (not great). It should be there instead of AC input in this…

Connecting the Multiplus 3000 to a BMS 12/200 via aux 1 and tsense port

According to this wire diagram: victronenergy.com US-Van-Manual-&-Drawing-Smart-BMS-CL12_100-MultiPlus-3kVA-12V-120V-60Hz.pdf 1347.34 KB you can use inverting remote on/off cables from the t sense port and the aux1 port to connect to the load and charge cut off on the bms. it says you have to upload these settings. does anyone know how to do this via the victron connect app? do I need different software? 5 posts - 4 participants Read full topic

Victron EV Charger in standalone with Cerbo GX and ET340

Good day All, We received a request for a Victron EV Charger. Please note that this Unit is standalone. We installed it with a Victron Cerbo GX and ET340. For some reason the EV keeps showing LOW SOC when plugging in the vehicle. We’ve tried to change the the register 5068 to one as shown in this link below, but the register returns to 0 when I change it to 1. https://communityarchive.victronenergy.com/questions/204970/ev-charger-automatic-charging-without-ess-system.html We’ve done a few with…

GbbOptimizer (a professional DESS alternative)

You can also try other DESS alternative: gbboptimizer.gbbsoft.pl Program has two optimizers: The first one try to discharge battery if during next 24h there will be too much power and/or charge battery if during next 24h you don’t reach 100% (or other defined MaxSco). It can be joined with Dynamic Scheduler to move schedulers to cheapest prices or Dynamic Discharch to discharge on highest prices. The second one is based on purchase prices, sale prices, value of energy in battery and maximizes…