Victron Community - Topics tagged professional

Topics tagged professional

Feature request - external transfer switch - S99 firmware

Current situation: When multiple compatible inverters are connected in parallel on the same phase, an external transfer switch must be used to establish a backup solution. For this case a special firmware must be used. Its called S99. Its well documented. When using an external transfer switch the master inverter of each parallel group relies on an external CT for its current measurements. This CT must be connected to the (master) inverter itself. Furthermore, the “AC OUT (1)” will be the main…

What is the relationship between VE.Bus "BMS lost" and "low battery alarm" timing?

I have a couple of systems in the field that are experiencing random shutdowns of their inverters. Everything else at the time seems to be “nominal”. Often there is no significant load. Mostly seems to be MultiPlus-II. The systems have had CAN bus cabling checked & replaced. CAN errors and actual BMS errors don’t appear to be a cause. They have had replacement GX units. Sometimes the VE.Bus state changes in the VRM history; sometimes it does not. The systems are otherwise reliable for days or…

Multiplus II VE.Bus Comms Dropping In and Out to Cerbo GX

Hi All, I have qty 2, 24V systems exhibiting the same symptom. 24V Lithium battery, coupled to Multiplus II 24/3000, coupled to Cerbo GX. The MP is connected to the Cerbo via VE.Bus. The VE.Bus cable is CAT5 and has been tested by myself. Cable is connected to the correct port in the Cerbo (I have tried both). The VE.Bus cable is routed away from 240VAC circuits and Inverter DC circuits in both systems. Other equipment can be a variety of Smartsolar MPPT’s (Multiple) and Orion DCDC’s. Where…

ESS neemt onnodig energie uit grid om accu te laden

Het ESS systeem is ingesteld op een minimale laadtoestand van 60%. Het screenshot is van 9:15 in de ochtend. De zon gaat schijnen en de warmtepomp staat aan op ongeveer 1000watt. Wat ik gehoopt had was een gebruik van de grid van 100 a 300watt. Maar het systeem besluit de accu te laden terwijl deze op 60% minimale laadtoestand ingesteld staat. Als ik de minimale laadtoestand aanpas naar 55% en dan terug naar 60% is het probleem voorbij. Wat ik denk maar niet duidelijk kan vinden is dat er een…

Multi RS Smart 48V/6000VA/100A - High temperature alarm

5 days ago one of our installations with the Multi RS Smart 48V/6000VA/100A started giving high temperature alarms and throttling solar productions every day as it can be seen from the pictures bellow. As the graphs clearly show, the PV productions of the Multi RS Smart 48V/6000VA/100A is clearly throttling when compared to the productions of the external MPPT, so it’s not a matter of shading our clouds. The panels on the Multi RS are facing East and West while the ones on the external MPPT are…

Failing inverters due to humidity

Good Night, Here at Paraguay, I investigating many installs the last 10 days, we conclude that we have a 70/30 rate of fails due to humidity and high temperature… Meaning 70% do very well as these were installed properly and 30% were not, this due to not skilled elecs at place…who didn’t place enough “cooling” to the “electrical room” sufficient… Our experience in West Coast Afrika (almost the same climate) and the South American will stay for the coming year, 30/70, please guys, place Propper…

Cerbo GX MK2 v3.85 Automatically Switch Inverter Mode OFF

Never had this happened before. So when we switch off MultiPlus 48/20000/250-100, using the toggle switches on the inverters, the next day we come back, switch the toggle back on, but the inverters still OFF. Checked all terminations, checked presence of 48V voltage, all good. Then we find that the Cerbo GX MK2 v3.85 automatically had the mode as OFF. Nobody touched that. Very weird. Is this a glitch? Anyone else experience this? What’s the solution? 10 posts - 4 participants Read full topic

BMV-812 Smart first impression

Hi everyone, We recently handed out more than 100 of the first BMV-812 units at the Victron distributor meeting, and I thought it would be nice to start a conversation here. The goal with the BMV-812 was to make a modern successor to the BMV-712 with a full-colour touchscreen. It’s a drop in replacement no need to update wiring or the shunt. These first units are running beta firmware. We are working hard to make the firmware feature complete for the first stable release. Historical, trend data…

Safiery STAR-Tank level alarms do not work, they are shown as warnings only on the (remote) console

Hello, we are using a Safiery STAR tank level sensor that transmits data via Bluetooth to a Cerbo GX. In the (remote) console, there are settings for high and low water level alarms (expressed as a percentage). On the preceding overview page, the statuses are clearly labeled as “Low Level Alarm” and “High Level Alarm.” Normally, these display as “OK,” but if a threshold is exceeded or fallen below, the status changes to “WARNING.” On the main console page, it also appears only as a warning (in…

Breaker Selection

hi all, Looking to install 3x Multiplus 2 - 15000 Units in a 3x Phase installation. I plan on having 8x Yixang V3 16KWH Battery banks installed. AC Coupled with 3x Fronius Primo 8.2.1 Units. Based in Australia. Curious what people use for issolation / Breakers on the Multiplus DC Side ? The Documentation suggests 2x 95mm2 cables with 2x 300amp Fuses on the DC supply side. What do people use for their breakers ? When i look up some DC breakers - they re highly expensive. Is it possible to push…

Quattro firmware update to suit CCGX OS 3.56

I’ve a system running faultlessly for a few years until a recent MPPT failure meant updating all the firmware to suit the (warranty replaced) new 250/100. 10kVA Quattro CCGX 250/100 Victron SpartSolar MPPT 20kWh BYD LVS My problem is that as per the attached images, the Quattro needs an update, but that update requires Venus OS firmware beyond what the CCGX can run. So how do I resolve this? Is there a firmware version for the Quattro that will cancel the notification AND be compatible with the…

Easee Smart Charging for Home Assistant: your EV charge plan in the VRM / Dynamic ESS forecast

Hi all, I’d like to share a free, open-source Home Assistant integration I built for my own Easee charger, and which now also talks to VRM / Dynamic ESS: Easee Smart Charging. It is available in the Home Assistant Marketplace (search for Easee Smart), and the source is on GitHub: GitHub - George-120/ha-easee-smart: Smart charging, Equalizer insight, charging costs and an app-style card for Easee chargers in Home Assistant · GitHub So this intregration is for very specific people with an Easee…

EVCS Gen1 – intermittent “CP input short circuit” error

I have a customer whose EVCS (Gen1) is giving intermittent “CP input short circuit” errors. This week, for example, it worked fine every day except Monday and last night. What has been checked so far: The client has already replaced the charging cable. Tested with two different cars (both plug-in hybrids): it seems to happen more often with the BMW, but it also happens with the Audi. Setup details: Firmware version: 2.09 Charging mode: Manual Installation: Indoor The documentation only says to…

GX Wifi Display verliert regelmäßig Kontakt zum GX Gerät

Hallo in die Runde, da ich in der Forumsuche nichts vergleichbares gefunden habe: Mein GX Wifi Display (Version 1.41) auf einem Lenovo TAB M9 mit Android 13 installiert zeigt alle paar Tage: “Unable to connect to GX Device” an. Reload hilft nicht, Menü der App ist erreichbar GX Gerät ist erreichbar richtiges WLAN und Internet sind erreichbar. Es hilft nur ein Reboot, dann funktionniert das Ganze wirder für ein paar Tage. Irgendjemand eine Idee oder Lösung? 2 posts - 2 participants Read full…

Feature request: quarter-hour net energy registration on VM-3P75CT / VM-3P5A

I’m using the VM-3P75CT and VM-3P5A meters in ESS installations in Portugal and would like to request a new energy registration method: interval (quarter-hour) netting. How self-consumption is billed in Portugal Self-consumption installations are billed according to the ERSE regulation (Reg. 815/2023). The DSO (E-REDES) calculates the energy balance (“saldo quarto-horário”) for every 15-minute period: total consumption minus total injection within that quarter hour. Only the net result counts:…

VRM release notes 11-11-2026

Hi all, I would love to share with you the latest changes that were just added to production VRM: Dashboard: when Dynamic ESS is configured but switched off, the energy price graph now stays visible. This way you can check the prices before switching Dynamic ESS back on. Dashboard: the EVCS control modes are now explained more clearly, so it is easier to see what each mode does. VRM within Victron Connect: the cards are now split into two sections, “Today’s totals” and “Live data”. We also…

VRM: Menü Steuerung funktioniert zeitweise nicht

Ich hab seit einiger Zeit in VRM öfter das Problem, dass das Menu “Steuerung” oben rechts sich nicht öffnet. Es erscheint nur “verbinden” und nichts weiter. Da ich das Thema schon von anderer Seite ebenfalls gehört habe, dachte ich stelle hier die Frage mal rein. Cerbo ist online, daran kann es nicht liegen. Browser ist aktueller Firefox unter Win11 1 post - 1 participant Read full topic

How to link Victron accounts in OneID

How does OneId work? How do I combine my old victron accounts into a new OneID account? I recently got automatically ‘upgraded’ from my vrm login account to Victron OneID, now I try to log in to my victronprofessional account and I again get the request to create a new OneID, this sounds a bit silly, is it One ID or do I still need a different ID for each service? How do I link my vrm account to my victronpro account? (I can link facebook/google accounts to my OneID but not Victron accounts??…

Double Check 3phase + Fronius

Hello, I am planning a 3 phase 50kw system. Connecting the Fronius and 3 x Multiplus together on the Ac bus using the ac input on the multiplus only. Below is my system diagram. Comms between fronius and Erkano via lan switch. 50kw battery is 4 x 13kwh battery with a JK BMS. Just checking I have not missed something. Many thanks Rich m 7 posts - 2 participants Read full topic

Generador se vuelve loco con MULTIPLUS

Hola Tengo dos Multiplus 5000/48/70 funcionando en paralelo con cerbo y un grupo electrógeno de 7kva, tengo picos de potencia al arrancar motores de poco más de 10kw y un consumo de trabajo de unos 5kw, cuando arranca el grupo electrógeno, la mayoría de las veces se vuelve loco y se acelera a tope, yo lo tengo limitado en intensidad o en VE CONFIGURE o en la propia pantalla GX, o lo paro el grupo o termina cortando por sobre potencia, además tenemos dos iguales, uno de reserva y con los dos…

Off grid AC PV coupling with generator

The system consists of the following components: 3x Quattros 15000VA 48V 230V on 3phase configuration 2x SmartSolar mppt 250/100 connected via ve.direct 1x Fronius Verto 33.3kW 1x CCGX 6x 16.6kWh poweroad Tervol L16 1x 3 Phase 20kVA generator The Quattros will form a 400/230 V, 50 Hz island network. The PV Inverter Support Assistant will regulate the Fronius through frequency shifting during inverter operation, with the Fronius configured for compatible MicroGrid operation (MG50 grid code). As…

VRM release notes 04-11-2026

Hi all, I would love to share with you the latest changes that were just added to production VRM: The Dynamic ESS chart on the dashboard now only loads once you scroll down to it, so the rest of your dashboard opens faster. On mobile devices, the Dynamic ESS chart now shows the time axis in 2-hour steps, just like the EV Charger chart. The labels no longer crowd together, which makes the chart much easier to read on a small screen. The AI assistant no longer jumps to the bottom of the chat…

Cegasa E/Bick Batteries - RS 450/200 Solar Charger Causing Battery Fault

New installation with bank of three E/Bick batteries (48V, 3x13KWH) and RS 450/200 Solar Charger: Initial startup went fine with the bank at ~95% SOC. The battery has a pre-charge function that brings the buss up to ~48V before closing the internal contactors. After running normally for a couple days, the bank was at 100% SOC and the system was shut down for some wiring work. The bank then failed to re-start. The bank would fault out during pre-charge and trip out. Pulling the battery fuse for…

Inverter Stop at Low Voltage pre Alarm in ESS

Hello everyone I have an customers Installation with Sodium ion (NA+) Batteries. We know for shure we can not take the full capacity of the batteries, because we dont get down to the dicharge volteges needed for that. Thats a fact, and we have to live with that limitation. But as we try to get the maximum out of the system, we have found some limits where i am not 100% shure if these are really limits or just a configuration issue. System Setup: 3x MP-II 48/3000 (3 Phase) CerboGX SmartSolar…