V
Does the VM-3P75CT & VM-3P5A log VA and PF in VRM as time-series data? I’m working with a customer that runs a summer camp off-grid on three phase diesel generators. They have no energy meters with logging and they can’t tell me what their peak and average loads and daily energy needs are since they don’t log the data. The camp uses three phase commercial equipment in the kitchen (i.e. mixers, refrigeration) and three phase septic lift pumps and well water pumps so I want to log VA and PF along…
V
Hello, We have an ESS system that is discharging the battery into the grid. It ignores the grid setpoint, the feed-in limit and the minimum SOC. I’d appreciate your help diagnosing it. SYSTEM 9x Quattro 48/10000/140-2x100 120V, 3 per phase, 208/120V 3-phase Phase masters: L1 HQ2243RK9HV, L2 HQ2146XUMEZ, L3 HQ2133RUDYN Cerbo GX, firmware 3.85, image type Normal (no Node-RED) Grid on AC-in 2; generator on AC-in 1 BSLBATT LFP bank (~8,000 Ah) with BMS on the Cerbo (CVL 56.0 V); DVCC forced on, max…
V
I tried to make my nucleo gx device to beep not only grid lost, but also when it return. I used node-red set 1 to com.victronenergy.system /Buzzer/State It beeps super small time like 15ms, even if you add loop for tens of times it still not be one long beep. Additionally loudness is also much smaller then normal one alert beeps. So my request is to add support at D-Bus API in Venus OS to be able add duration parameter or a “beep until reset” mode, that venus-platform doesn’t override. 1 post -…
V
We install Victron battery systems and Viessmann heat pumps every day, so you can imagine how excited we were when EEBUS integration was introduced! Today, we completed our first installation combining Viessmann and Victron with EEBUS. Getting the two systems connected was surprisingly easy. In Victron, you simply enable EEBUS, and in the ViGuide app, you scan for EEBUS devices. Viessmann discovers Venus, and Victron detects the Viessmann heat pump. However! The connection doesn’t seem to be…
V
I look after a site which has 3 Victron Quattro 48/15000/200-100/100 230V in 3 phase config It is an off grid installation I randomly get an error on all 3 at exactly same time:- Temperature L1’ on ‘VE.Bus System [276] Temperature L2’ on ‘VE.Bus System [276] Temperature L3’ on ‘VE.Bus System [276] Then instantly get:- Temperature L1’ cleared on ‘VE.Bus System [276] Temperature L2’ cleared on ‘VE.Bus System [276] Temperature L3’ cleared on 'VE.Bus System [276] The error times and cleared time…
V
I have some issues with Shelly 1 Gen 4 devices that just disappear from the VRM and Cerbo. They are being used as 12v smart switches. Latest version have done it over multiple versions 20260923-075739/2.0.1-ge1a198b Cerbo 3.85 but has similar issues going back to 3.70 which were supported to have been fixed. All devices have static IP address and reserved in router, eco mode is off, they respond from the Shelly app and work as expected but just disappear from anything victron. Any suggestions,…
V
hi, we have two separate systems where the generator autostart isnt working, including with genset. we dont have battery monitor or shunt. we have gone through all the manuals and datasheets to ensure that it has been installed/connected correctly with the right settings and they all seem to be correct. however, both systems seem to still not be responding to the generator autostart. does anyone have any advice on what we have done wrong or how we can fix this? thank you. 5 posts - 4…
V
Hallo liebe Victron-Fans, ich habe das Problem mit dem Licht überall im Haus, was auf derselben Phase hängt wie mein 3D-Drucker. Während des Druckens machen die Motoren so krasse Lastwechsel, dass das Licht flackert. Der zieht noch nichtmal viel Leistung (zwischen 50 und 300W), aber die Lastwechsel scheinen dem MP nicht zu gefallen. Gibt es dafür Abhilfe? Ich denke an ein Gerät, das ich vor dem Drucker in die Steckdose stecke, das die Lastwechsel wegpuffern kann? Danke und Gruß, Heiko 33 posts…
V
Hey all, So we’re trying to diagnose some issues with modbus communication between the GX and an Enphase gateway / microinverter array. A few questions that have come up: Is it still not possible to delete redundant entries from the PV inverter list on the console? It seems that Enphase has changed how the device presents and now I have multiple entries - I just want to delete them all and start again? I’ve seen several topics on the issue, including one where it was said that the functionality…
V
In North America, we split a single phase AC grid connection into two phases with 180° phase rotation. This question could also be applicable to three phase systems connected to one or two phases on the AC input. In either case, “switch as group” would be disabled in VE.Bus System Configurator to allow connection to just one phase on the input side. The question: Does the firmware in the inverters properly handle the ground relay in such a configuration? Let’s say we have an RV or a boat that…
V
Hey Everyone, My system setup is- Multiplus II 5000 GX, Fronius Primo 5kw AC coupled(AC Out) with 7.5kw of panels, a Smart Solar 250/70 with 3.6kw of panels and a 24Kwh BYD LVS battery. The system is grid tied and allows export of 5kw. I have just tried to setup opportunity loads with a Shelly 1PM on a hot water heater for the first time and having problems. The shelly is all setup and on the same network as the Multiplus GX, it shows up under devices in the GUI and have configured it here as…
V
Hi, Currently, only alarms can be ‘pushed’ from nodeRED as a notification to someone’s phone. However it would be extremely useful for me as system installer/programmer to also send INFO notifications via the app. e.g. when the SoC reaches a certain minimum, a temperature a certain level, EV charger starts or any other significant event. Hence, a request to add INFO class notifications that can be triggered in nodeRED. 1 post - 1 participant Read full topic
V
Hi all, I would love to share with you the latest changes that were just added to production VRM, most of them on the dashboard: On the dashboard, temperature cards for Ruuvi sensors now show an extra “Air quality” row, with a score and a label that tells you at a glance what that score means. The minigraphs (the graph in the dashboard cards) and Dynamic ESS graphs on the dashboard now refresh automatically. So if you keep VRM open on a screen all day, or your laptop or tablet wakes up from…
V
Used power assist in mobile applications and that is configured in VE.Config. But, when in ESS mode its controlled with the following (as I understand it): Limit Inverter Power in ESS menu Limit system AC import current in peak shaving / Grid current limit However some of these settings can be set in a few places, which one takes priority? I am trying to limit the total power available to the house fuse box to 100A, example 60A from grid and the 40A from Multiplus (I already have 100A fuse on…
V
Hi Victron Community, I need to know some information regarding the MPPT limitation for high current PV module, I am working on a project where I have the inverter from Victron which is Multi RS 48/6000/100 and it has dual MPPT trackers. Each tracker is compatible to connect 1 PV string each. So, I have designed my PV string with the panel from Jinko which has a model name: JKM620N-66HL4M-BDV, The STC of the panel are as follows: P(max): 620W V(mp): 40.74V I(mp): 15.22A I have connected 5…
V
Continua la discussione da Validazione schema parallelo di 9 Multiplus 15K Trifase ( 3x3): In un sistema trifase con 9 Multiplus 15K (3x3) e con transfer switch esterno, gli AC Input dei 6 slave vanno o no connessi alla rete AC in ingresso? La mia richiesta nasce da un chiarimento chiesto da un importante cliente di sistemi BESS che supportiamo su importanti progetti a cui abbiamo già inviato il file Victron di approfondimento 1. Introduction Ringrazio per l’help di chiarimento In a three-phase…
V
Hallo, hat jemand hier eine Idee ? Meine Anlage mit zwei zusätzlichen Fronius WR regelt leider die Leistung der MPP`s herunter. Habe zwei My PV AC Thor 9S verbaut aber die Anlage regelt die Leistung auf 50,2 Hz ab, so daß die Heizstäbe nicht den vollen Strom abbekommen. Wieso nur ? Fronius WR bringen zusammen fast 2000 W, aber die PV Module, die an den MPPT`s hängen ( mit voller Südausrichtung ) bringen zusammen gerade mal 90 W. Möglich wären aber 27 KW !´auf der MPPT Seite, und fast 12 KW auf…
V
I have a customer with an off grid system that has been installed for some years with a MP2 5000VA inverter. Histotrically they powered mainly lights, heating pumps and had an immersion set up as a rudimentary opportunity load (OL) switched via inverter settings and the relay on the MP2. They have recently added a large home extension with a variety of new appliances including an induction hob, oven, more lighting, washing machine (hot fill) and dishwasher, max. individual load of 2.9kW on a…
V
There is something confusing here… In the MPPT RS range of products, on the product brief present on the Victron website, PDF dated April 15, 2025, so about one year and a half ago, it says: PV Isolation fail level (4) - 100 kΩ Note 4: The SmartSolar MPPT RS will test for sufficient resistive isolation between PV+ and GND, as well as PV- and GND. If the resistance falls below the threshold, the unit will report an error and send an error signal to the GX device (if connected) for audible and…
V
Hi all, I would love to share with you the latest changes that were just added to production VRM: Dynamic ESS: users with read-only access to an installation can now see the Dynamic ESS settings. They cannot change anything; the wizard and the on/off switch stay closed to them. The event log tells you a lot more: Installation notes now show who wrote them and the note text. More events now show who performed the action. A new entry is added when someone generates or downloads a site report.…
V
Greetings to all, I represent a non-profit youth athletic complex in the Tampa Bay area that is trying to build a low voltage (12 volts) off the grid system that incorporates a Victron MPPT, a Cerbo-GX, Smart Shunt and other equipment to run 3-4 POE CCTV cameras and an access point. I have purchased 85% of the equipment and got over my head with this project. I am looking for a professional builder who can finish this system for me. Once this project is completed there might be a second system…
V
Yesterday my VRM App on my iPhone 14 lost its login for no apparent reason. In attempting to log back in on my iPhone, I enter my email, a new window opens, a progress bar advances and disappears, but the page never loads. It remains empty and the log in process does not advance. VRM on my desktop devices still works normally. I use Brave as my browser and have since I’ve had the App. The issue does not change if I turn off Brave protections for victronenergy.com, so I don’t suspect Brave being…
V
Dear Victron Community, I am using a Victron BlueSolar MPPT 100/20 charge controller connected to a Cerbo GX through its VE.Direct port. We would also like to connect an MPPT Control display to the same charge controller for local monitoring and configuration. Since the MPPT 100/20 has only one VE.Direct port, we would like to clarify the following: Is it possible to connect both the Cerbo GX and the MPPT Control display simultaneously using a VE.Direct Y-splitter? If a standard Y-splitter is…
V
Hallo, wir hatten jetzt schon mehrfach das Problem, dass ein Microgrid während dem Betrieb ausgefallen ist. Das System besteht aus 3x 48V/15kVA Quattros. Die Einstellung für ‘Microgrid’ ging verloren - wir haben die Konfiguration heruntergeladen und mussten es neu einstellen. Nach dem Upload hat es wieder funktioniert. Hat jemand eine Erklärung hierfür? Wir schalten das Microgrid bei Batteriestand weniger 8% aus - folglich war also Batteriespannung beim Einschalten vorhanden. Ebenso liegt…
V
Hola a todos: Quisiera comunicar un posible fallo relacionado con la limitación de potencia de entrada de red en las últimas versiones de Venus OS. Mi instalación dispone de un Cerbo GX, tres MultiPlus-II 5000 conectados en paralelo monofásico y un sistema ESS. En VEConfigure tengo configurado un límite de corriente de entrada de 63 A y la opción Dynamic Current Limiter está desactivada. Desde septiembre de 2026 he observado que el sistema no importa más de aproximadamente 10 kW de la red…
V
We are using the following system: parallel three-phase system with 2 Quattro-II’s on each phase Venus OS: v3.81 stable VE-bus: Quattro-II 48/5000/70-2x50, firmware 2651558 On October 9, 2026 at 03:27 both the console and VRM display the following AC output data: Phase Current Power L1 62,1 A 7.625 W L2 37,3 A 4.269 W L3 35,3 A 4.119 W It looks like the displayed AC output current on each phase is twice as high as expected based on the reported AC output power. Does anyone recognize this? 1…
V
In trade mode, there are a number of conditions specified. The system ignores the time intervals with the highest price and exports 50% of the maximum grid export threshold. Instead, the system tries to charge the batteries first, with an SOC currently sitting between 70 and 80%, and with discharging from the battery allowed. Initial data: from 06:00 to 11:00, conditional maximum export tariff is 15 cents from 11:00 to 20:00, conditional export tariff is 11 cents from 20:00 to 06:00, export…
V
Hallo zusammen, hat noch jemand zwei My PV AC Thor 9S in einem Inselsystem am laufen, und wenn ja, wie habt ihr das programmiert ? Über Modbus TCP, also mit IP Adresse in den AC Thor, oder rein über Frequenzabhängige Regelung ? Die 3 MP bringen ja zusammen nur 15 KW zusammen, den Hauptanteil sollen aber die Fronius bringen. Daher die Frage, Wenn ich über MODBUS den Cerbo das regeln lasse, regelt der das dann so, da er weiß daß 2, später sogar 3 Fronius im System hängen, oder muß ich rein über…
V
Hi all, we’re seeing an intermittent start failure with a three-phase compressor load on a 3× MultiPlus-II system and would appreciate input from anyone with experience of large motor loads. System 3× MultiPlus-II 48/6k5/100-50, three-phase setup on VE.Bus Cerbo GX], DVCC enabled 3× Victron Lithium NG 51.2 V / 100 Ah, Lynx Smart BMS NG, Lynx Distributor Inverter-only operation (no AC input connected during the tests) Load Three-phase compressor motor, approx. 9.3 kW, rated approx. 20 A at 400…
V
Есть трехфазная система из 6 Quattro 15000 по два параллельно на фазу Интересует обновление инверторов через Remote VE.Bus firmware update. Во вложении я показал одну фазу AC–out. Инструкция по обновлению пишет, что есть промежуточный этап, когда инвертора включаются с дефолтными настройками, до загрузки конфигурации. В связи с этим возникает вопрос: безопасно ли то, что два параллельных инвертора одной фазы в данный момент объединены своими выходами, пока не загрузилась конфигурация системы 14…