Victron Community - Latest topics

Latest topics

MultiPlus 12/3000/120 all of a sudden not reading battery voltage correctly

Hi - I purchased a system from AM Solar in Arizona, USA, 6 or so years ago, including a Victron Multiplus (12/3000/120) inverter. The system has been absolutely great, and the support I have received from AM Solar has been top notch. However, they have gone out of business and I don’t know where to turn for help. I just seem to have developed a problem with the Multiplus. It seems to be reading erroneous voltage from the battery bank. It jumps all over the place, between 13.2 volts up beyond 5…

Inverter VE Direct 500VA - LED Alarm/Error Sequence

I have a the inverter powering an efficient fridge and a couple of other low power items – LED lighting and TV. When powering these devices the inverter is fine with no alarms and battery voltage is approx 25.75-85V. I am using the remote switch to turn it off with a NC relay, so when I switch on shore power or a 3000VA inverter to supply higher power devices, the NC contacts are opened. When using shore power, charge only and 0 amps on the Multiplus remote panel i.e. in the AC transfer mode,…

Sistema trifase con 9 Multiplus II 48/15000 in parallelo trifase abbinato con generatore AC

Continua la discussione da Validazione schema parallelo di 9 Multiplus 15K Trifase ( 3x3): In un sistema trifase con 9 Multiplus 15K (3x3) e con transfer switch esterno, gli AC Input dei 6 slave vanno o no connessi alla rete AC in ingresso? La mia richiesta nasce da un chiarimento chiesto da un importante cliente di sistemi BESS che supportiamo su importanti progetti a cui abbiamo già inviato il file Victron di approfondimento 1. Introduction Ringrazio per l’help di chiarimento In a three-phase…

Corrupted BMS-Can values on Cerbo GX traced to Ethernet duplex mismatch

Sharing this in case it saves someone a month of troubleshooting. In my case a network problem on the Cerbo’s Ethernet port showed up as corrupted battery data on the BMS-Can port. System Cerbo GX, Venus OS v3.75 → v3.80 (no difference between versions) 9 × Pylontech US5000 on the BMS-Can port (BMS firmware v1.6 as reported by the GX) MultiPlus-II 3-phase, ESS with Dynamic ESS Home Assistant reading the GX over Modbus TCP, later also over MQTT Symptom Every now and then a single sample from the…

3 × MultiPlus-II 48/10000 dreiphasig, 65 m vom Zählerschrank – interne Relais oder ETS (Stromwandler

Hallo zusammen, ich plane eine ESS-Anlage mit Ersatzstrom für das ganze Haus und komme bei der Frage nach dem richtigen Aufbau und der Zertifizierung für die Netzanmeldung bei Westnetz nicht weiter. Geplanter Aufbau 3 × MultiPlus-II 48/10000/140-100 als Dreiphasenverbund Fronius Symo GEN24 10.0 SC am AC-Out MPPT RS 450/200, LFP-Akku ca. 64 kWh Scheinleistung = 3 × 10 kVA + 10 kVA = 40 kVA, daher ist ein zentraler NA-Schutz (Ziehl UFR1001E + Kuppelschalter) ohnehin nötig Die Geräte sollen ca. 65…

Validazione schema parallelo di 9 Multiplus 15K Trifase ( 3x3)

Trovo per me poco esaurienti le informazioni sul parallelo trifase del manuale 3. Installation Mi sembra di capire che, con il tranfer-switch esterno, venga richiesto il collegamento dell’ AC Input solo per i 3 Master delle fasi L!-L2-L3 Allego uno schema che mi servirebbe validato. Ringrazio per l’Help 2 posts - 2 participants Read full topic

Multiplus II- nur über AC2 betreiben?

Hallo, Ich möchte meine Solaranlage erweitern und auf Victron umsteigen. Paneele derzeit noch über ac inverter angebunden. RS450 noch geplant um die Akkus dann aufzuladen.. Setup soll den angeschlossenen PylonTech laden und entladen können, gemäß Energymeter. Cerbo ebenfalls geplant. Frage mich, ob ich mit unten stehender option1 meinen Akku geladen / entladen bekomme - oder ob es zwingend option2 benoetigt(oder ggf. Eine andere Verschaltung)? Vielen Dank 2 posts - 2 participants Read full topic

Affichage graphique de l'historique de la production grisé

Bonjour à tous, Je dispose d’une installation composée: Multiplus II 48/10000 MPPT 450/200 5 batteries Pylonthec US5000 Cerbo GX (Firmware 3.81) Le Cerbo GX dispose de carte SD de 32GO formaté en Fat32, j’ai testé l’écriture sur la carte SD afin de vérifier si elle n’est corrompue. La tuile de la production sur la vue d’ensemble n’affiche jamais plus de 2 barres L’affichage de l’historique de la production n’est visible que sur la journée encours et hier jamais plus, et de plus l’onglet…

Multiplus II-GX : Installation CPI côté batterie en défaut

Bonjour, afin de doter d’une capacité de stockage mon système solaire basée sur des micro-onduleurs ENPHASE, j’ai installé un convertisseur MULTIPLUS II-GX et des batteries PYLONTECH US 2000C. Lors de l’analyse de mon dossier, le CONSUEL m’a confirmé la nécessité de fonctionner en régime IT sur la partie batterie et d’installer un CPI. J’ai opté pour un DOLD 5881.12/100, qui vient couper le convertisseur en cas de défaut. Le schéma de mon installation est ici : 20261019 - schéma installation…

Venus OS v3.81 – Problema con la calibración de sensores MOPEKA

Título: Problema sensores MOPEKA Hola: Tengo un Cerbo GX con Venus OS v3.81 y dos sensores MOPEKA que miden el gasoil de los depósitos de mi barco. He configurado las curvas de calibración personalizadas para que los litros indicados correspondan a la forma de cada depósito. El problema es que, después de reiniciar el Cerbo GX, las curvas siguen guardadas, pero parece que dejan de aplicarse correctamente y los litros indicados no corresponden con la calibración. He vuelto a introducir las…

Multi RS solar PV oversizing

Dear Community, I’m in the process of building a setup with 3 Multi RS solar systems. At first to convert PV to 230V but also to be prepared to add batteries in the future. The MPPT input of the Multi RS will be coupled to 20 * 480Wp Aiko PV panels (7S+7S+6S) Here originates my question. The Aiko 480Wp panels are capable of providing 13.92A The Multi RS solar Maximum operational PV input current: 12 A per tracker Question: what will the operation method of the Multi RS be when a current larger…

AC Thor 9S Leistung der Victron Anlage Cerbo ?regelt leider PV Ladegeräte herunter, wieso?

Hallo, hat jemand hier eine Idee ? Meine Anlage mit zwei zusätzlichen Fronius WR regelt leider die Leistung der MPP`s herunter. Habe zwei My PV AC Thor 9S verbaut aber die Anlage regelt die Leistung auf 50,2 Hz ab, so daß die Heizstäbe nicht den vollen Strom abbekommen. Wieso nur ? Fronius WR bringen zusammen fast 2000 W, aber die PV Module, die an den MPPT`s hängen ( mit voller Südausrichtung ) bringen zusammen gerade mal 90 W. Möglich wären aber 27 KW !´auf der MPPT Seite, und fast 12 KW auf…

VRM graph x axis offsets - suggestion

Hi, I noticed that values in the VRM graphs are drawn on the x-axis with an offset of half an hour. This is the case both in VRM on the web and in the VRM app. Both bars and points show this behaviour. See the example below, in this bargraph the bars are centered on the full hour. However the period for which the value is given is from 7:00 to 7:59. In this layout the bar suggests it represents an average or total taken from 6:30 to 7:30. I propose the bars are centered on the half hour, so…

EasySolar-II_GX and Cerbo_GX compatability

Hi Can anyone tell me if it is possible to disable a internal gx device in a EasySolar-II_GX so that I can use a Cerbo_GX with a touch 50 instead? I have a system with 2 x 250/100 mppt’s, a smart shunt and a EasySolar-II_GX along with 4 x batteries making a 48v system. The Cerbo_GX has a starlink Ethernet connection and I can see the 2 mppt’s and the shunt but I can’t talk to the EasySolar-II_GX. It was connected to the Cerbo via a VE direct cable. Is this the correct way to connect it to the…

: Kan ik twee Orion XS-laders aansluiten achter één BatteryProtect 220A

Hallo allemaal, Ik heb een Ford Transit camper uit 2021 met een slimme 230A-dynamo. Momenteel heb ik een Victron BatteryProtect 12/24V 220A tussen mijn startaccu en een Orion XS 12/12-50A zitten. Dit werkt uitstekend. Nu wil ik een tweede Orion XS 12/12-70A parallel aansluiten achter dezelfde BatteryProtect. De gezamenlijke ingangsstroom zal naar verwachting ongeveer 130–145A bedragen, dus ruim onder de 220A. Ik lees waarschuwingen over de inschakelstroom van condensatoren bij gebruik van een…

Konfiguration Inverter

Hallo miteinander, hätte eine Frage zur Konfiguration eines Phoenix Inverters 12/1200. Haben die automatische Abschaltung auf 12 V Batteriespannung eingestellt (Blei Säure Akkus). Er schaltet sich auch brav ab, wenn ich dann aber die Batteriespannung mit der App prüfe, dann zeigt mir sowohl der Laderegler (SmartSolar MPPT) als auch der Inverter eine Batteriespannung von 12,4 V an. Es sieht also so aus, dass das System die Kapazität der Batterien nicht voll ausschöpft. Oder gibt es einen so…

Wire type selection for MPPT 100/30 connection

I’ve chosen 8 AWG copper wire to attach my Victron 100/30 to the in-line 40 amp fuse, and from there to a 100aH LIFePO4 battery on the positive side, and 8 awg copper for the negative side of the controller to the battery. Victron recommends multi-stranded wire. Is there a clear preference between 8 AWG Ultra Flexible Stranded Wire, 1650 Strands of 0.08mm Tinned Copper, or 8 Gauge Battery Cable with 186 strands of 24 ga copper? Should I use ferrules with either choice, or is bare wire…

Camper-Setup - ich habe ein paar Fragen

Hallo in die Runde - ich habe schon die Suche bemüht, leider jedoch keine passenden Artikel gefunden. Es geht um unsere Campster, der über folgende Konfig verfügt: 120 W PV auf dem Dach 1x BlueSolar PWM-DUO (SCC010020060) 1x Electronicx LiFePo4 mit 100 Ah 1x SmartShunt 500A Grundsätzlich funktioniert das Setup - ich habe allerdings festgestellt, das wohl ein paar Sachen nicht korrekt konfiguriert waren. Unter anderem war wohl b01 (also Blei) im DUO eingestellt - die Ladung hat natürlich bis ca.…

MP2 3000/48 als Notstromladegerät

Hallo,ich verwende einen 4 MP2 als Ladegerät für die Pytes V5 akku,der MP2 wird von einem 5kVA Dieselgenerator mit avr regelung gespeist.Der MP2 speist für ca. 2 Minuten die Pytes und dann schaltet er ab ohne ersichtlichen Grund.Mit VE Config ist der MP2 ohne Grid,erweiterter Frequenzbereich,Dynamische Strombegrenzung,UPS deaktiviert und schlechte Eingangsspannung Parametriert. Die eingangsfrequenz ist max. bei 52,2 Hz,Strom auf 13 A eingestellt.Das sollte soweit passen aber trotzdem schaltet…

SSH removed from Cerbo 3.81?

A few days ago, I updated my Cerbo GX to v3.81. I’ve now noticed I can no longer SSH into it. Also, previously, you enabled SSH and set the password from Settings → General. But SSH is no longer listed. I have a few custom things running on my Cerbo - the driver for controlling batteries over a serial connection, the great Dr Volt Aggregate battery plugin too as I have several batteries. I can no longer set that up unless I can restore some kind of SSH access. I’ve checked Setup → General →…

Victron XS short circuit

Advice please if you will? So, I just had to change the wire strain plate on my Orion xs. I stripped a screw and had to drill it out and left it in until I sourced a new plate. I left the charger in-situ and stupidly didn’t disconnect power. It’s in an awkward cupboard. As I removed the broken plate away from the unit the screwdriver fell and hit the cable(s) at the terminals and there was a bit of a spark. The app showed no obvious faults. I drove and monitored it moved through it’s cycle of…

Batterieentladung verhindern

Gibt es eine Möglichkeit die Entladung des Akku zu verhindern ohne den Rest zu beeinflussen? Hintergrund: Ich habe ein normales ESS. Alle Verbraucher sind hinter den Batterie-WR angeschlossen. Wenn nun die Sauna angeschaltet wird, laufen zusätzliche 8KW aus der Batterie. Ich “halte” aktuell die Entladung mit dem SOC-Schieberegler an. Kann man die Entladung hart abschalten? Die “Wechselrichter-Leistungsbegrenzung” regelt, kommt also nicht in Frage. Es muss nichts dynamisches sein. In der Zeit wo…

Appendices missing in EasySolar-II GX 4k5 manual

The manual of the EasySolar-II GX 4k5 contains the appendices E through G. Unfortunately, the manual also references appendix A and appendix B. Am I missing something obvious about where to find these appendices? I would like to reference appendix B (specifically relay H). Is that the only relay to ground in the wiring diagram of the 4k5 datasheet? Merci! 6 posts - 3 participants Read full topic

1x MP-II 48/5000 ESS on L1 in 3-phase house, last check before I buy

After reading/lurking on the forums for a few months, I feel I have my design in order - discussed with my electrician, and the Click&Design website numbers seem plausible too. But, since this is the first time for him building a system like this (his core business is rewiring old houses, not adding battery systems) I’d like to check on a few safety items based on your collective experience here. This will be a mostly DIY build, with all wiring checks and utility connections performed by the…

Opportunity loads and load shedding in an inverter overload scenareo

I have a customer with an off grid system that has been installed for some years with a MP2 5000VA inverter. Histotrically they powered mainly lights, heating pumps and had an immersion set up as a rudimentary opportunity load (OL) switched via inverter settings and the relay on the MP2. They have recently added a large home extension with a variety of new appliances including an induction hob, oven, more lighting, washing machine (hot fill) and dishwasher, max. individual load of 2.9kW on a…

Erreur #67 sur 3x MPPT 450/100 (Batteries Pylontech + LV-Hub) – Blocage de production

Bonjour à tous, ​Je sollicite votre aide suite à un blocage de la production solaire sur mon installation. ​Description de la configuration : ​Régulateurs : 3 x SmartSolar MPPT 450/100 ​Parc batteries : Pylontech gérées avec un LV-Hub ​Communication : Câble de données BMS / CAN relié au système GX ​Le problème : Mes trois chargeurs MPPT 450/100 affichent l’erreur #67 - Pas de BMS (ou BMS connection lost). Du coup, les régulateurs coupent la charge par sécurité et la production solaire est…

MPPT RS PV isolation information / capabilities

There is something confusing here… In the MPPT RS range of products, on the product brief present on the Victron website, PDF dated April 15, 2025, so about one year and a half ago, it says: PV Isolation fail level (4) - 100 kΩ Note 4: The SmartSolar MPPT RS will test for sufficient resistive isolation between PV+ and GND, as well as PV- and GND. If the resistance falls below the threshold, the unit will report an error and send an error signal to the GX device (if connected) for audible and…