XIO

xWire

Posts from every feed QUEST has found across the web — blogs, news, podcasts, channels and more.

Victron Community - Latest topics

Latest topics

Boat Page gadgets and one annoying thing

Hi All, I have recently discovered Node Red and have made some pretty cool little “gadgets” with it, to enhance my digital dashboard (aka the Renote Console). Through some virtual devices I have managed to show my not-so-smart Bow Thruster and Starter batteries’ state and switch on or off the AC charger for the thruster battery that I have hooked up to a Shelly device. Pretty fun to build and nice to have For the Boat Page, I have routed the data from my physical temp sensors to a virtual…

Community Guidelines

Welcome to the Victron Community This is a place to ask questions, share ideas and learn from each other. Beginners, enthusiasts and experienced professionals are all welcome. Most answers come from volunteers, so please be patient and give the community time to help. For official support, warranty enquiries or help with an installation, follow the Victron support process. Be welcoming and respectful Help others feel comfortable asking questions, whatever their experience or first language.…

No dynamic ess prices octopus UK

For the last three days I’m getting no dynamic ess prices for my UK system with Octopus agile. Prices are available in my Octopus account so not sure why my system not getting values. AFAIK my system has not been changed and was working perfectly. Any ideas what’s happening? 1 post - 1 participant Read full topic

Dynamic prices octopus UK

For the last three days I’m getting no dynamic ess prices for my UK system with Octopus agile. Prices are available in my Octopus account so not sure why my system not getting values. AFAIK my system has not been changed and was working perfectly. Any ideas what’s happening? 1 post - 1 participant Read full topic

Second Quattro QUA488024000 (fw 499) in parallel + mixed US5000/US3000C Pylontech bank

Hello, I have a single-phase ESS system and plan to add a second identical inverter in parallel. I would like to confirm a few points before buying. Current system Victron Quattro 48/8000/110-100/100 230V VE.Bus, part number QUA488024000, serial HQ22266QHE3, product ID 0x2655, VE.Bus firmware 2655499 (499) Cerbo GX, Venus OS Large 3.80, ESS Assistant, MK3 MPPT 450/100 and MPPT 450/200 (38 panels) Pylontech bank, 4 modules now: 2 × US5000 (100 Ah) and 2 × US3000C (74 Ah), 348 Ah in total (about…

Updated community guidelines

Fellow members, as part of ongoing improvements to the community, it has become necessary to update our guidelines to reflect what the community is now and to be more relevant for the modern online user. The previous ones were perfect for the time the community was originally launched but haven’t kept up with changing requirements. We hope this will provide a less ambiguous guide to new users, and crucially, a good foundation for the moderation team to help keep this community a relevant and…

Garmin missing Relay 1

My relay 1 is setup as a manual switch. It appears in the VenusOS interface as well as VRM. However, it does not appear on my Garmin watch. I have also configured a switch from a Shelly 1 Gen4, and it appears on my watch, as well as relay 2. 1 post - 1 participant Read full topic

Access to vrm portal

I sent installation id a few weeks ago and nothing. got a cerbo gx used i can access acress from my network and would like remote access . i got remote console but no vrm portal . I have the app installed and cerbo is on ethernet cable. i tryed to send xlsx file but wont let me. everytime i try to send it says bad file type. i remote into my other stuff on my network no problem to turn off stuff like lights and other things . AM I MISSING SOMETHING? 7 posts - 4 participants Read full topic

EVCS hat wieder keine Verbindung mit CCGX

Hallo, Leider besteht erneut ein Verbindungsproblem zwischen meinem EVCS und dem CCGX. Die Internetverbindung beider Geräte ist intakt, jedoch wird der EVCS auf dem CCGX als „nicht verbunden" angezeigt. Zudem lässt sich am EVCS der Akkustand nicht abrufen, und über VRM gibt es keine Einstellungsmöglichkeiten für den EVCS – obwohl das Smart Solar dort zwar vollständig mit allen Daten sichtbar ist, aber keinerlei Steuermöglichkeiten bietet. Interessanterweise konnte ich gestern trotz bereits…

Shore Limit showing impossible option

I have a system running a Quattro 2 24/3000/70-2x50 2x120v connected to a Cerbo GX Mk2. In recent versions of Venus on GUIv2 if I click to change the input limit the top option is 63A (which is greyed out because it’s impossible on the system), and the next down is 32A. There’s no 50A option, so I’m having to hit the 32A button and then hit + until it gets to 50. This happens on both the current release and betas. Screenshot is attached below. 3 posts - 2 participants Read full topic

Help with MPPT 150/35 Bluetooth Connection

I have purchased a used 2025 Airstream Basecamp. When trying to connect via Bluetooth, my MPPT will not connect due to a previous pin. I have tried all the default ideas (000000, 0000, 1234, etc.) I would like to reset. I have scoured the MPPT and no label with PUK # is attached. My MPPT does not have a mode button. I have called Airstream, they cannot help. I have S/N but can’t find anyone who might be able to supply PUK#. Just for Clairification…NO Label with a PUK# is on the unit. Not front,…

GRID Feed-in with DESS and battery at 100%

Hi, I’m a newbie and have the system now active for 1 week and really like its capabilities. This is my current setup: What I noticed is, that when my battery is at 100%, the system stops taking energy from the PV charger and doesn’t feed it back to the grid anymore. Even though I have these settings active: I have a dynamic contract and would want the system to inject any excess energy into the grid, especially on sunny days when the batteries can easily get charged. Any…

[BUG / possible regression] ET112 watt value freezes when Cerbo S GX UI enters idle state — Venus OS

I am seeing a reproducible New UI display-update issue on a Cerbo S GX running official Venus OS v3.81. Setup Cerbo S GX Venus OS v3.81 official release New UI / GUI v2 Victron ET112 energy meter ET112 used to monitor the AC consumption/output of a non-Victron inverter Behaviour The ET112 power reading updates normally while the Cerbo display is active. Approximately 10 seconds after the last touch input, the Cerbo UI appears to enter its idle/low-power display state. At that point, the…

Virtual Indicator shows up in VRM as "Expansion IO" – can't create widgets/graphs for its values

Hi all, I’m using the new Virtual Indicator node in Node-RED on a Venus OS Large test system and I’m running into a limitation in VRM. I’m posting it here to check whether this is expected, planned, or whether I’m missing a setting. Environment Venus OS Large 3.81 node-red-contrib-victron: [version from palette manager] VRM portal (production) What I did I created four Virtual Indicator nodes (two Discrete, two Value type) in the same Group, “Calitatea aerului” (air quality), fed from a flow…

Orion XS reverse charging with dual Orion XS units: feature request automatic disable

The new feature is AWESOME! I have two features I am hoping are in the works. So first question may just be is there a outlook for updates tot he feature that are planned? One I am looking out for is a trickle charge style setting. I have a feeling that one may be in the works though. The other I am wondering if others have the need because I imagine it may not be as high priority and possibly has other solutions to make it work. That would be a sort of automatic disable of the second Orion in…

Multi RS Solar: Balancing 3 phases incorrectly during 'Keep batteries charged'

Hi everyone, Yesterday evening, I noticed the following behavior in my system: L1 was importing around 2100W, while L2 was exporting a similar amount of power back to the grid. I have no idea why the system felt the need to compensate for the phases in this way. It doesn’t seem efficient at all when you consider the charge and discharge efficiency losses. Has anyone seen this before or knows what might be happening here? System details: • Situation: The battery bank was balancing at the time,…

VRM App (IOS) and VRM web portal show different data (SOC)

Hello Victron team. VRM App (IOS) no longer shows any data for SOC (Battery Monitor widget) while VRM web portal still does . Why different behaviour? This happens since a couple of weeks/months only. Release bug ? See below screenshot for both VRM App and Web Portal (same time). Thanks for your answer , Christian 1 post - 1 participant Read full topic

DESS stays "Off" on Multi RS 48/6000, balancing message never clears

DESS is enabled in VRM (trade mode, Tibber NL), but the dashboard keeps showing “Dynamic ESS – Off” with no schedule. The Multi RS shows “External control”. Firmware: Multi RS 48/6000/100: v1.31 (VictronConnect says latest) Cerbo GX MK2: Venus OS v3.81 VictronConnect: v6.43 Battery: 2x Pylontech on CAN Already tried: toggling DESS off/on, rebooting the Cerbo, updating firmware (Cerbo from v3.67, Multi RS from v1.26), BatteryLife off, Modbus TCP off. I also see “Battery balancing is scheduled…

Android GX Display v1.4 released

GX Android Display v1.4 Hi all, Version 1.4 of the GX Android Display app is available. It is a maintenance release and finishes the job v1.3 started: the blank screen after waking the display, which v1.3 was meant to fix and did not. There are no new features. How to get it Displays with automatic updates enabled will install it by themselves during the night. To update straight away, open the configuration menu by pressing and holding the lower left corner of the screen for five seconds, then…

Victron ESS im Allgäu – 28,5 kWp PV, VW-NMC-Speicher und 128 kWh LiFePO4-Erweiterung

Mein Victron-ESS im Allgäu – 28,5 kWp PV, Sonnen-System, Fronius und 128-kWh-LiFePO₄-Speicherprojekt Hallo zusammen, ich möchte euch unsere etwas umfangreichere PV- und Batteriespeicheranlage im Allgäu vorstellen. Die Anlage ist über viele Jahre gewachsen und wurde immer wieder erweitert und umgebaut. Wir planen, bauen und betreiben vieles selbst. Unser langfristiges Ziel ist, unsere Energieversorgung möglichst vollständig unabhängig vom öffentlichen Stromnetz zu gestalten. Momentan…

Is it normal to have AC Out drops when the grid is lost?

Hi everyone, I have my Multiplus II 48/6k5 GX for some 2 full months now and I have fixed most issues which were mostly from my lack of knowledge of the various parameters (I installed the device myself based on the many hours of reading and watching videos). My installation has an AC Coupled Huawei inverter which holds the solar panels. There is a 16KW Dyness battery as well. Just today the grid was out for 4 hours and I am very happy with the investment so far. The PVs continued to produce…

Adjusting DESS EV consumption forecast via Node-RED – HTTP 429 and local alternative?

Hi, I’m working on a charging planner for two cars, using Node-RED on a Cerbo GX. The idea is to calculate when the cars should charge, based on electricity prices, required energy and departure times. I would like to send the expected EV consumption to DESS so it can take this into account when planning battery charging and discharging. I’m running Venus OS 3.81 with VRM-DESS and victron-vrm-api v0.4.4. I managed to get the post-adjust-consumption function working. I can add an EV consumption…

Black Resin Dripping from Multiplus II 48/6k5 - unit was working fine

I noticed these drips today on top of the DC Isolator. The Multiplus II 48/6k5 is located right above. At that time the unit was working fine. Inverting/charging, just the usual. Not very hot to the touch. Maybe a little more transformer hum than usually, but that could be my imagination. There are more drips on the battery box, further below. On the battery box they are spread quite wide. Not dripped straight down. I can only assume either they were spread out by falling through the fan, or…

Cerbo GX Röle kapalı olmasına rağmen VRM de röle görünüyor

Merhaba arkadaşlar. Victron Cerbo GX ile webastomu çalıştırıyorum. Cerbo GX üzerinde bulunan 2 rölenin birini AÇMA tetiklemesi diğer röleyi KAPATMA tetiklemesi olarak kullandım. Node-RED üzerinden bu kontrolleri hazırladım ve Röle ekranına gösterdim. Sorunum 1. Röle için Node Red ile açma kapama bölümü eklememe rağmen Cerbo GX üzerinden röle gösterimini kapatmama rağmen VRM portalda istemediğim röle hala aktif görünüyor. VRM Portaldan bunu kapatamıyorum. Görünmesini istemediğim bölüm GX Cihazı…

MultiRS 6000 minimum voltage

Hi all. I have a multi RS6000 and am using both of the solar array input ports (so 2 plus cables and 2 minus cables to be absolutely clear) as I have an east/west garden (panels are ground mounted) and putting them in series into just one of the input ports causes low production levels due to partial shading. I have 66V coming into both solar input ports. The manual says that the DC input range is 38-62V. I am sure that this is not referring to the solar input since the maximum DC voltage is…

EV charging : cannot get more than 2kw of solar power

Hi, I have a Cerbo GX connected to a MultiPlus-II 48/5000/70-50, ESS enabled. I’m looking for a way to force solar power into my EV rather than using it to charge the house battery. Right now, I can only get 2kw of power from the solar panel. If I increase the vehicule charging power, then the additional power is taken from the grid instead of the solar panels. 8A charging seems to be the limit : If I increase the power of the charging vehicule (here to 12 A), it starts draining power from the…

Multiplus I 24/3000/24 - Battery Selection and Charging Voltages

The MP has a number of battery types. I am selecting " Flooded Tubular Plate" for TAB 2V cells 9EPzS810L. However, I note that the check box “Use equalisation (tubular plate traction battery curve” then becomes unchecked. The absorption voltage is 32V and I understand from the documents that the equalisation voltage is 2V above, so 32V. If selected, there is a warning that voltage may rise to 34V. I just wondered what the background is. 3 posts - 2 participants Read full topic