Multiple SOC alerts
I want to create multiple SOC alerts at different levels, but in VRM using the Lynx BMS as the device, I can only create 1 alert at a given SOC level. Any ideas how to solve this? 2 posts - 2 participants Read full topic
Posts from every feed QUEST has found across the web — blogs, news, podcasts, channels and more.
Topics tagged marine
I want to create multiple SOC alerts at different levels, but in VRM using the Lynx BMS as the device, I can only create 1 alert at a given SOC level. Any ideas how to solve this? 2 posts - 2 participants Read full topic
Hello, I just connected a new Orion XS 70 (firmware 0x115FF) with a VE Direct cable and I am tracing the output. I have some interesting findings: After the standard text mode output, there is always a set of asynchronous HEX mode sentences, not always the same and the one sent are depending on the state of the device. More troubling, many of these sentences have ID that are not documented in the Orion XS VE direct documentation. Some examples of unknown ID: 0xE000, 0xEE10, 0xEE11, 0xED56,…
The VRM interface item for a DCDC charger is an “alternator” and this reports the output voltage The output voltage (ie the house battery in most installations) is available in a few other places - MPPT, BMS etc… To monitor the charge state of the starter battery and alternator operation it would be useful if the input voltage was reported in VRM The input voltage is clearly detected by the DCDC charger to trigger charging It is also possible to set an alarm on the input voltage (which is handy…
I intend on installing a Victron Blue Smart IP 22 charger 2 output in my boat for charging my house battery and starter battery (lead acid). I have a battery selector connected to both batteries so I can choose to use the starter battery for house loads or the house battery for the starter. So, the switch also allows both batteries to be connected in parallel. In case I am charging both batteries with the switch off and then switch to parallel, how will that affect the charging? 1 post - 1…
In Australia and New Zealand, lithium installations must be compliant to AS/NZS3004.2, which requires the BMS to give an audible and visual alarm at the normal operating position before a disconnection event. I’m working out the cleanest way to do that with the REC, and I’d like to hear from anyone who has already done it and had the system accepted as compliant. I’m fitting an REC 2Q BMS (Victron CAN firmware) to a 24 V LiFePO4 bank, 2P8S, on a boat with a Cerbo GX, MultiPlus 24/5000 and…
Trying to program 24v Quattro 2 5000 for gen pulse start and stop. Under assistant config. There was from memory a pulse setting. Sure I’ve done it before in victron configure. [moderated. AI content removed as per our guidelines] 10 posts - 4 participants Read full topic
I have a legacy ESP PowerMan AC-CO-110A/PL/3xM controlling three MultiPlus units. Following a shore power interruption and restoration at the marina, the ESP panel now permanently displays 000V and 000A on both shore and generator supplies. Generator indication still works correctly and all charging/inverter functions operate normally. F1 on the PowerMan PCB was found blown and has been replaced, but the fault persists. Are any schematics, repair information, replacement boards or modern…
Use case I install and service marine electrical and electronic systems in San Diego. Have been in the industry for 35 years and work closely with Jim Dixon here. On larger yachts, getting VE.Direct devices connected to a nav station or helm mounted GX display can often be difficult due to the longer cables required on larger yachts. Orion XS DC-DC chargers near an engine or alternator, and SmartShunts on a remote bank can be 10–20 m of cable away. VE.Direct and USB can de troublesome at those…
I am using a Smart Battery Sense together with a Cerbo GX running Venus OS Large and Node-RED. The Smart Battery Sense provides both battery voltage and battery temperature via Bluetooth/VE.Smart Networking. In my setup the temperature is used by other Victron devices, but it is not available as a measurement in Node-RED on the Cerbo GX. It would be very useful if the Smart Battery Sense could be exposed as a device/service on the GX system, with battery temperature. Ideally these values would…
I have a W-connection on my alternator that I use with a physical gauge to show the RPM. I would also like to have this visible on my Cerbo’s Boat dashboard. I have read that I should use an optocoupler like a PC817 to get the signal into the digital I/O of the Cerbo to not cause any damage. Can anyone confirm this is the safe way to do this? 4 posts - 3 participants Read full topic
Hi everyone, We are working on several marine applications using Victron systems with lithium batteries, Cerbo GX, Quattro/MultiPlus and MPPT solar chargers. Previously, we did not need to implement any special software logic for battery SOC limits. However, with larger solar arrays on newer boats, we are now facing a different requirement. When the boat is connected to shore power in the marina, the customer does not want the batteries to be charged to 100% continuously. Can this type of…
Phantastic, that a reverse emergency charging has been implemented and is available as a firmware update! Thank you, Victron. As my use case is on a sailboat and in combination with a Cerbo GX (connected via VE.Direct), I wish that this function could also be accessed from the Cerbo (i.e. the Venus OS). I could even imagine to wire such an emergency reverse charge function with a button acting on a Cerbo input and a LED connected to a Cerbo output showing that it is active. It would be great if…
We have a new build narrowboat and the fresh water tank level has been problematic since delivery. It swings around by 100-150 litres based on time of day with a capacity of 800 litres. We coped with it, but now the boat is laid up for winter can see it is just moving daily - and knowing correlation <> causation - it appears to be falling as system voltage rises when solar cuts in then recovers when the solar drops off. Most times overnight the signal is stable when the batteries sit at a…

I have a sailing boat in Greece with 4x 100 Ah lead batteries in serie ( 3x service and 1x start) and a 15 yr old Victron solar system which I would like to replace/ upgrade Currently average solar production is 500 Wh with 2x 80 Wh panels I have fridge and inverter as consumers What would be the ideal panel / mppt configuration to replace? Thank you for comments and help 5 posts - 2 participants Read full topic
I’ve been building a phone app that reads Victron data locally, and this seems like the right crowd to share it with. What it does: Reads the encrypted Instant Readout BLE advertisements from Victron devices (SmartShunt, MPPT, Orion-Tr / XS, Phoenix inverters, Smart Battery Sense, VE.Bus, AC chargers). You paste each device’s encryption key once and it decodes on-device. Connects to a GX over MQTT (Cerbo, Ekrano, Venus OS): plaintext 1883 on the local network, or over a VPN/Tailscale by…

Have an older Multiplus 1, 12/3000-120 that does not invert from battery power to 220V. This is in a boat. All lights are good Inverting click or sound is OK No error messages Pass thru from land shore is OK. When inverting from 12V, it says in VE bus that AC output L1 is 1W, 0,07A. Battery is fully charged. 220V fuse that comes on when pass thru does not light up, when inverting from battery. Main DC Fuse from DC is OK (250A fuse), ohm measured and measured DC on MP. It seems like everything…
We purchased a Star Power Safiery digital switch last year and have it set up in our electric boat with a Victron Ekrano and use it to switch lights and pumps. After first upgrading to Venus OS large 3,7 and later to 3,72 we are noticing that in both OS instances the Victron Ekrano sometimes (randomly) does not detect the Safiery after the Safiery StarPower has been switched on. The ekrano incorrectly reports that it is not connected. After rebooting the Ekrano the safiery is found and…

My 7 day old Cerbo Installation just sent me a 4am alert that the communication dropped. IE, wifi no longer connected. WTH. I went to the boat and the green and blue lights were blinking. I connected with my phone over BT and could see it was no longer connected to the WiFi. I tried reconnecting and it would not. I tried connecting to a couple other connections at the marina that are farther away but usually are connectible. No luck. I removed power and upon repowering, it connected. I assumed…
Hello, first big boat trip with my new Victron Config/installation on my 55’ motor yacht. This morning I received an Alert via email about an overload on one of my MPII Inverters. The Alert cleared after 20 seconds and I suspect it was a spike/load from my wife using the Microwave, toaster oven, and coffee maker at the same time. Problem is the Alert contains very little detail. Is there any way to get more detail in the Alerts? Overview pic of the components in my system, Alert originated from…

Hi everyone, I’d be really grateful for any pointers on this, as I am completely stumped. I installed the Multiplus C 12/2000-80 on my boat together with 2 new 300Ah Lifepo4 batteries. Wired everything up, fused for 300A between Multiplus and batteries and each battery fused again with 250A. 70mm² cabling and a no more than 1,50m between Multiplus and batteries. Voltage drop from battery to Multiplus DC input 0.01V. Switched on for the first time yesterday. Everything worked fine. Had AC power,…

I have installed a Wakespeed 500Pro alternator regulator with Cerbo GX mk2 and smart Lithium batteries to operate in DVCC mode with the alternator info visible on the Cerbo. and am struggling to get it working fully. I have two scenarios as follows: I can get the system to work nicely in DVCC mode if the 500Pro and batteries are both connected (& properly terminated) to the Cerbo at 500bps baud rate (500Pro LED flashes orange indicating slave mode and the charge current is controlled by the…
I have a new system with 3 Orion Chargers 2 running off of a 1030 ah agm bank and 1 running off a single agm start battery, these agm batteries are charged by 2 separate alternators. They are all outputting to a 1840 ah lithium bank which powers all AC loads on the boat through 2 Magnum inverter chargers. The Orions are connected to the recipient battery via a Lynx distribution bus bar approximately 4’ away using max size cable for the Orions. When underway using engines and a light load on the…
I use a pair of Veratron J1939 <> N2K engine gateways to get RPM and engine run time information into my N2K network. That hardware will send tank information from each engine control panel to N2K as well, even though those inputs on the engine are not connected to a tank level sensor (they are already on the N2K bus with a Yacht Devices Tank Adapter). This results in 4 fuel tanks being displayed on my Cerbo GX, though two are empty. These get consolidated into an overall fuel level, so without…
Hi, I have 4 x 12v lithium ng 300ah batteries in Parrallel, connected with Lynx power in and Lynx BMS NG. All running latest firmware. After two months since I last charged it up (and cells were balanced) I connected the boat to Shore Power to recharge, and batteries had 30% remaining. I have now done three recharge cycles with 8h absorption charge for balancing using the skylla 65Amp charger, and the batteries only reach 88% charge (I could sync this soc value) but the celles continue to say…

Rookie question perhaps, but I currently use a SmartSolar 100/30 charger to connect my 520W Smart panels to my 24V lead-acid starter batteries, which also feeds an Orion 24V/12V dc-dc charger for my 12V domestic batteries. Both battery sets are also fed directly by conventional 24V and 12V alternators. I’m changing the 12V batteries to Lithium - is it good idea to use an XS between the 12V alternator and lithium battery, while the Orion is still connected to it? Is there a problem with the two…
I have installed a Cerbo GX in my boat and connected to 12 V power supply and SmartSolar MPPT 100/20 via VE Direct cable. The wifi and Bluetooth diodes light both up. The Cerbo GX shows up in the VictronConnect app on my Andriod phone, but I cannot connect via Bluetooth. The progress bar goes to 95 and the restarts a couple of times before showing a no connection message. I’ve tried to disconnect the Cerbo GX Bluetooth connection, restart my phone, re-installe the VictronConnect app and restart…
According to this wire diagram: victronenergy.com US-Van-Manual-&-Drawing-Smart-BMS-CL12_100-MultiPlus-3kVA-12V-120V-60Hz.pdf 1347.34 KB you can use inverting remote on/off cables from the t sense port and the aux1 port to connect to the load and charge cut off on the bms. it says you have to upload these settings. does anyone know how to do this via the victron connect app? do I need different software? 5 posts - 4 participants Read full topic
Hi, I’m looking for some help reviewing a wiring diagram I’ve created. If anyone has time to check not only the wiring but also suggest alternative products or improvements I may have overlooked, I would really appreciate it. This is my second larger system using Victron products. The first time, I built a system for a motorhome. With help from this community, My family and I lived in that motorhome without any power issues for 18 months. Now it’s time again, but this time it’s for a boat. The…

Hi, I have a 12V marine setup with a Lynx Smart BMS, Lithium Batteri Smart, MulitPlus II, DC/DC, Cerbo GX, GX Tuch and some other components. What I now realize is that I cannot measure the start battery (lead) from the Lynx Smart BMS (as I would do with a standard shunt). Anyone having a good idea how to measure start battery voltage in a setup with a Lynx Smart BMS? Can the analog I/O on Cerbo GX be used? I want the information to be displayed on the GX Touch. The start battery are not…
The prod guide for the Multiplus II says “This inverter is provided with an internal isolation transformer providing reinforced insulation” There are a couple of old threads asking whether this means that a separate galvanic isolation transformer for shore power input is not required for marine use, but none of the answers is really clear about what the internal transformer actually does and whether a separate GI transformer is still required. Can anyone give a definitive answer to this?…