V
Hi, currently i have three 100Ah batteries connected to a Cerbo on a boat. When the boat is not in use only the Cerbo (with 4G LTE) is drawing power which is a very small load of <0.5A. The BMS in these batteries unfortunately does not monitor loads under 1 to 1.5A. So they won’t notice the power draw, don’t update the SoC and will prevent the batteries from being charged (CCL = 0A). In about three weeks the batteries are drained to <10%. A workaround is initiating a higher load, like turning…
V
Good Morning, on a 100’ sailing boat I replaced 3 x BMV-600 to BMV-712 because I need to connect them to Global Link 530. The yard which built the boat installed the small BVM electronic board far from the shunt, behind the panel where is located the screen and using a twisted cable . Probably due to some magnetic fields on the calbe way, on the screen I always read about 4-5 Amperes of discharge, even I disconnect the load cable from the shunt (I measure about 0,9 mV between the shunt arrival…
V
I have a standby generator on my home which was installed by a previous homeowner. Brand is Generac, pretty common in the US. But it’s about 20 years old and doesn’t have any monitoring built in. I want to monitor the starter battery. Someone on a different discussion board suggested Smartshunt. The Smartshunt manual refers to using the AUX connection for a starter battery. This sounds to me like an RV or boat that has a house battery and a separate starter battery. In my case, I only have a…
V
Hi everyone, I’m looking for some solution on my solar charging setup on a Regal MPPT-Anschlussplan.pdf (1,5 MB) motorboat. My current setup is: Victron SmartSolar MPPT 150/35 Victron smallBMS NG 2 × Victron Lithium NG 12.8 V / 200 Ah batteries (400 Ah total) 2 × Offgridtec 225 W solar panels connected in parallel (450 W total) Victron Cerbo GX with GX Touch MPPT connected to Cerbo GX via VE.Direct What I want to achieve: I want the smallBMS NG to automatically stop solar charging whenever the…
V
Hi all, I’m leaving my boat on the hard in Whangarei, NZ, for about 13 months. Temperatures stay above freezing. System (basically drawing BJE-286B, attached) 3 × Lithium Battery Smart 12.8V/330Ah in parallel Lynx Smart BMS 500, Cerbo GX SmartSolar MPPT, approx. 600 W PV MultiPlus 12/3000/120 (shore power / Honda 1000i), Balmar alternator All charging controlled by the Lynx via DVCC, default settings (14.2 V / 13.5 V) The problem The obvious plan is to charge to 100%, switch the Lynx OFF with…
V
I’m looking into the install of the Multiplus II 24-5000 on our sailboat. I am uncertain of the ground wiring. Does the diagram below look correct? (At the breaker panels all grounds are tied together) The top breaker panel is shore only, the lower is either shore or Inverter. The inverter is not planned to be used as a shore power pass through when on shore power, except the rare case of using it to charge the batteries. (I do have another charger that can deal with the crappy power here..…
V
All, I bought a boat not knowing much about the Victron system installed. So it has a phoenix inverter, 2 victron smart batteries (200 ah each) 2 bluesolar charger, a bmv 700 battery monitor and an old VE.bus bms. Also ACR s to the starter batteries and alternators. The BMS is not hooked up and one of the batteries bms connector is broken. I can fix the wire but my question is this. What is the best way to get this system safe? I know i can run wires to the solar chargers to shut them off if…
V
A newbie asks for help from a guru! I have a MultiPlus 12V 3000 VA 120 AMP on board. See also attached product label for all details. It is a stand-alone, single phase installation. The printed out manual which received when the MultiPlus was built into my boat some years , only mentions DIP switches. However, also some years ago, I was told by a different Victron specialist that there are settings, which need to be done using VEConfigure, MK3 adapter, and a RJ45 cable. I can in the meantime…
V
2 invertors one for each curcuit but using the same battery bank to draw power see i have power on L1 but not on L2 4 posts - 4 participants Read full topic
V
This is a sailboat installation. In Nov of 24 we replaced all the solar panels and charging equipment with Victron products. It was installed by a licensed professional and the system has been working flawlessly until last week. System breakdown 6x 460w panels controlled in pairs with 3x MPPT 100/50. Firmware v1.74 Cerbo S GX Multipluss 3000 inverter charger 4x 300ah Relion Lithium house bank We are currently sailing in the Solomon Islands and have been receiving exceptional solar input Last…
V
24 V marine system, currently specifying a replacement house bank: six Lithium NG 25.6 V/300 Ah in parallel (1,800 Ah), Lynx Smart BMS NG 1000, two Quattro 24/5000/120, six SmartSolar MPPTs, Cerbo GX MK2. Total installed charge capability is about 593 A, which is 0.33C. The datasheet derates charge to 0.3C above 35 degrees C. On this bank that is 540 A against my 593 A, so the derate is not academic for me. What I cannot find is the enforcement path. The BMS manual (5.6.3) says the Parameters…
V
Hi, I have a boat with 7 Victron smart bluetooth devices. At wintertime in Scandinavia I´m away from the boat for months at a time and would love to have a simple VictronConnect bluetooth/WiFi bridge so I check the status of my power system. I don´t want to connect a Cerbo GX with 3 VE.Direct cables, a powered USB hub and 4 VE.Direct to USB interface cables just to be able to check the status once or twice a month. I don´t need a realtime status display of my system like the Cerbo GX, just the…
V
I am getting confused by the different temperature readings. Since 2 months I have 2 Victron LifePO4 NG 25.6 V 300 Ah batteries on my yacht. I keep a close eye on cell voltage, balance and the temperature. Yesterday I had measurement of 46 degrees showing on the dashboard of VRM and on the Remote Console. That scared me. When I checked the the detailed temperature of the cells, it said it was only 14 degrees. So now I am confused. See screenshots. Where is the measurement of 46 degrees coming…
V
Hi all, Good day. May I ask if anyone has experience connecting two Victron 100A Buck-Boost DC-DC converters in parallel, using a single alternator, to increase the overall charging current? Would appreciate any insights or recommendations. Thank you! 2 posts - 2 participants Read full topic
V
My BMV700 often shows 100% charged when I had expected it to take longer to charge. Its installed on a boat, and for example we can discharge the 360AH bank by 100AH then perhaps charge at 50amps. So I would expect 2 hours till fully charged (assuming constant current) but it often indicates 100% after about 1 hour. Is there a setting on the BMV700 that I should check, I am fairly sure I have the capacity set to 360AH but will check. 13 posts - 6 participants Read full topic
V
I want to use as much PV as possible while connected to shorepower. So I made a flow that tries to set the Input Current Delimiter to just below the power needed to supply the loads. This is calculated every 10 seconds and when the outcome differs enough, it is changed in the settings. Thus (in theory) letting the PV do as much as possible to keep the batteries charged and supply as much of the loads as possible, during the day. When PV is gone, the Input Current Delimiter is set to a higher…
V
Hi All, I have just had a new victron system installed on my narrow boat - Cerbro GX, Orion Smart, SmartShunt, Smart Solar, SuperPack NG. The smart shunt isn’t showing the correct state of charge - it often shows 100% charge when the SuperPack NG shows around 20%. I think the electrician who installed it has wired it up wrong. He has connected the negative of my starter battery to the negative of the SuperPack NG which in turn is connected to the smart shunt. This doesn’t seem to be correct…
V
Hi, I’ve successfully connected a bilge pump and high level flow switch (via an opto isolator) to my Cerbo. I’m able to set them up as devices and see their state on the Cerbo’s display. What I’d like to be able to do it track the pump’s daily run times, and number of cycles plus send an alert if the pump has run continuously for more that a configurable time period. I’ve built (with a bit of AI help) a NodeRed flow that exposes that data to SignalK quite successfully. I’ve also posted it back…
V
Hi everyone, I’m replacing the old 230V installation on my Najad 340 and plan to install a MultiPlus-II 12/3000/120-32. The MultiPlus will be about 5 metres from the main AC distribution panel. Both AC outputs will be connected using 3 × 2.5 mm² cable. The distribution panel has individual 30 mA RCBOs for all final circuits (B10 and B6). I’m trying to work out the correct protection for the two 5-metre cables between the MultiPlus and the distribution panel. My main concern is AC-OUT-1 when…
V
Hi Victron team, The VRM dashboard tile for a Meteo device currently only shows Irradiance (W/m²). On my boat there is no irradiance sensor, but I do have wind data. I publish it as a Meteo device using the Node-RED virtual device (node-red-contrib-victron), with the /WindSpeed path in m/s. What works: - The GX device shows “Wind speed 4.2 m/s” under Settings > Devices > Wind. - The value is available in VRM Advanced, where I can graph it. What doesn’t: - On the VRM dashboard the tile only…
V
After changing batteries in the Ruuvis, only one is seen by cerbo. They have both been working fine for 3 years before this. I can see both in the ruuvi app. Any advice? 4 posts - 3 participants Read full topic
V
Hi, My ship is going on the hard for the winter. I would like to keep the inverter running to power my modem and a security camera, but not connect it to shore power. Can this be done safely? I will keep the battery charged with my solar panels and can connect a separate bluepower victron charger every once in a while to keep the battery healthy. Any safety issues here? 6 posts - 4 participants Read full topic
V
I am planning to install Orion XS DC to DC converter on my Jeanneau 36i sailboat. I have a relay which makes start and service batteries in parrallel ( shunted) when aternator starts producing DC current. What is the best practice for installation? I have 2 options in my mid. Un mount the relay and connect Orion in place of the relay Keep the relay but interset Orion between the service battary and the existing relay. Option 2 has the advantage of disconnecting service batts immediately after…
V
In North America, we split a single phase AC grid connection into two phases with 180° phase rotation. This question could also be applicable to three phase systems connected to one or two phases on the AC input. In either case, “switch as group” would be disabled in VE.Bus System Configurator to allow connection to just one phase on the input side. The question: Does the firmware in the inverters properly handle the ground relay in such a configuration? Let’s say we have an RV or a boat that…
V
I have a the inverter powering an efficient fridge and a couple of other low power items – LED lighting and TV. When powering these devices the inverter is fine with no alarms and battery voltage is approx 25.75-85V. I am using the remote switch to turn it off with a NC relay, so when I switch on shore power or a 3000VA inverter to supply higher power devices, the NC contacts are opened. When using shore power, charge only and 0 amps on the Multiplus remote panel i.e. in the AC transfer mode,…
V
My B&G Zeus3S 12 plotters connect to the boat LAN over WiFi only, and the Victron MFD app tile has never appeared on them. The Cerbo (Venus OS v3.81) announces the tile using its 169.254.x link-local address, which WiFi clients can’t reach, even though it also has a normal LAN address. As a test, I resent the Cerbo’s announcement with its LAN address instead, as a subnet broadcast (e.g. 192.168.1.255:2053). The tile then appears, and the app works with live data over WiFi. A Signal K plugin…
V
Hi All, I have recently discovered Node Red and have made some pretty cool little “gadgets” with it, to enhance my digital dashboard (aka the Renote Console). Through some virtual devices I have managed to show my not-so-smart Bow Thruster and Starter batteries’ state and switch on or off the AC charger for the thruster battery that I have hooked up to a Shelly device. Pretty fun to build and nice to have For the Boat Page, I have routed the data from my physical temp sensors to a virtual…
V
The MP has a number of battery types. I am selecting " Flooded Tubular Plate" for TAB 2V cells 9EPzS810L. However, I note that the check box “Use equalisation (tubular plate traction battery curve” then becomes unchecked. The absorption voltage is 32V and I understand from the documents that the equalisation voltage is 2V above, so 32V. If selected, there is a warning that voltage may rise to 34V. I just wondered what the background is. 3 posts - 2 participants Read full topic
V
Unfortunately through a series of failures I’m trying to recover severely discharged SmartLithium 330Ah batteries on my boat, one battery at a time. Equipment: SmartLithium 330Ah, 12V system Victron PMP122200102 MultiPlus 12/2000/80-50 120V VE.Bus, UL 458 (80A charger; current/non-Compact model) VE.Bus BMS V2 Cerbo GX Balmar XT170 (170 Amp) alternator with MC-618 external regulator The batteries were drained for a few days and read 2.5V at the terminals. I know, very bad. I’m using the recovery…
V
Hi everyone, I have a Cerbo GX on my sailing yacht and recently installed a Shelly Pro 1PM to switch and monitor my 230V / 16A shore power connection. The Shelly works fine with Venus OS. I can switch it and see the power measurements. What I don’t understand is why Victron only allows the Shelly to be used as an AC load meter, not as a grid or shore power meter. I would really like to see the shore power voltage, current and power directly in the AC input section of my Cerbo GX and VRM. Is…